FSE's containerized water chillers are designed for maximum protection and convenience. They operate in demanding environments. Installed in durable, dust-proof containers, they withstand harsh conditions. This ensures reliable performance even in challenging outdoor settings. Designed for easy mobility, they allow quick repositioning. Minimal on-site preparation is required. This makes them ideal for large-scale construction projects. The units provide precise cooling with cold water output temperatures ranging from 1°C to 5°C. This ensures optimal concrete cooling under extreme conditions. It also offers flexibility and protection during transportation and deployment.
CCl Containerized lce Water chiller (1°C output) | |||||||
Model | CCI60 | CCI120 | CCI180 | CCI240 | CCI312 | CCI360 | |
Daily Capacity (Tons/Day) | 60 | 120 | 180 | 240 | 312 | 360 | |
Cold Water Flow Volume (m³/h) | 2.5 | 5 | 7.5 | 10 | 13 | 15 | |
Necessary Refrigeration Capacity (kw) | 130 | 260 | 390 | 520 | 675 | 780 | |
Installed Refrigeration Capacity (kw) | 147.25 | 290.1 | 411.95 | 571.7 | 696.1 | 820.7 | |
Coefficient of Surplus | 1.13 | 1.12 | 1.06 | 1.10 | 1.03 | 1.05 | |
Total Power Consumption (kw) | 48 | 82 | 143 | 183 | 199 | 261 | |
COP (kw/kw) | 3.50 | 3.76 | 3.31 | 3.38 | 3.67 | 3.29 | |
Container Specification | 20' | 20' | 40'HQ | 40'HQ | 40'HQ | 40'HQ |
CCl Containerized Cold Water chiller (5°C output) | ||||
Model | CCT180 | CCT240 | CCT300 | CCT360 |
Daily Capacity (Tons/Day) | 180 | 240 | 300 | 360 |
Cold Water Flow Volume (m³/h) | 7.5 | 10 | 7.5 | 10 |
Necessary Refrigeration Capacity (kw) | 130 | 260 | 390 | 520 |
Installed Refrigeration Capacity (kw) | 147.25 | 290.1 | 411.95 | 571.7 |
Coefficient of Surplus | 1.13 | 1.12 | 1.06 | 1.10 |
Total Power Consumption (kw) | 48 | 82 | 143 | 183 |
COP (kw/kw) | 3.50 | 3.76 | 3.31 | 3.38 |
Container Specification | 20' | 20' | 40'HQ | 40'HQ |